Skip to main content

6026 How to access keypad programming the GV3 Panel.

Keypad programming is available in GV3 panels with firmware revision 8.10 or higher. 
NOTE: Keypad programming is not available during while an RPS programming session is active, or when any area is armed.
Enter from normal operation:
  1. Press [9]+[9]+[Enter].
  2. Select Keypad Programming. The keypad displays Enter Passcode.
  3. Enter the service passcode (default= 123).
Enter from service mode (reset pin closed):
  1. D1255:
    1. Set the address to 16 with dipswitch: 1-5= OFF and 6= ON. The keypad displays Enter Passcode when the reset pin is closed.
    2. Enter the service passcode (default= 123).
  2. D1260:
    1. Set the address to 8 with dipswitch: 1-3= OFF and 4-6= ON. The keypad displays Enter Passcode when the reset pin is closed.
    2. Enter the service passcode (default= 123).
The following options are available upon entering keypad programming:
  • Phone Numbers – Phone 1 thru Phone 4
    • Phone Format - Phone 1 thru Phone 4
    • Enhanced Comm – Path 1 thru 4
  • Routing
    • Route Groups 1 thru 4
  • RPS Parameters
    • RPS Passcode
    • RPS Phone Number
    • RPS IP Address
    • RPS IP Port
  • Area Parameter – 1 thru 32
    • Account On – Yes / No
    • Account Number
  • Command Center 1 thru 16
    • Enhanced Command Center – Yes / No
    • Command Center Scope –
  • User Pass Code
    • User 0 (Install Passcode)
    • User 1 (User Passcode)
  • Point Parameters
    • D9412GV3: 1-247
    • D7412GV3: 1-75
    • D7212GV3 1 -40
    • Point Index
  • Disable Keypad Programming

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.