How to address and where to connect the DX4010V2 or DX4010i.

7000/9000 Series panel types thru GV3 panel types:

Connect the DX4010i or DX4010V2 to the SDI Bus.  7000/9000 and G tyes must use terminals 29-32.  GV2 and GV3 types can use the 4-pin molex connector labled SDI or the 4-pin molex connector labeled SDI.

GV4 panel types:

GV4 Panel types have connections for both the SDI and SDI2 bus.  SDI and SDI2 are different types of busses, the DX4010V2/DX4010i will only work when connected to the SDI bus.  Connect the DX4010V2/DX4010i to either the 4-pin molex connector labeled SDI or use terminals 29-32.

DX4010V2 Addressing by panel type.png

When addressed and connected correctly to a compatible panel, the red LED will flash at a 1/2 second rate. 

The Installer Switch must be Closed / Locked on D4412 or D6412 panel types  in order to connect to RPS.

 