How to correct the D4412/D6412 only reports to one destination and not following programmed routing.
The D4412 and D6412 provides an ability for individual areas to send reports to only one of the two programmed destinations rather than follow standard routing.
The setting described below in figure 1 displays how to Lock Area Programming to either Destination 1 or Destination 2. To revert back to standard routing, select Disabled in this parameter.
Using keypad programming, make a selection in the desired area as using the programming nibble as described below . Default setting=0 (Disabled).
Area 1: 0297
Area 2 (D6412 and D4412 only): Nibble: 0319
Area 3 (D6412 only): 0341
Area 4 (D6412 only): 0363
Nibble Selections:
0 = Disabled
1 = Destination 1
2 = Destination 2