How to determine if the D5360 is compatible with the GV3 panel.

  • The D5060 Direct Connect interface is used as a direct connect interface for connection to Remote Programming Software.
  • The D5060 Direct Connect interface is compatible with GV3 panels using firmware versions between 8.00 and 8.09.  GV3 types with version 8.10 and higher must use another type of interface with Remote Programming Software such as the DX4010V2. 
How to determine the firmware revision of the GV3 control panel:
Using a text keypad such as the D1255, press [CMD] + [59] to determine the panel revision. If the panel revision displayed is between version 8.00 and 8.09, the D5360 is compatible.

D5360, D7412GV3, D7212GV3, D9412GV3, D1255