How are zones/points disabled in programming in the DS7400 Series panel?

  • Enter programming using the Default pin plus # 0 (default pin = 9876).
  • The keypads will display Program Mode X.XX.
  • There are 4 versions of the panel.
  • Version 1 will read Program Mode 1.XX, Version 2 will be 2.XX, Version 3 will be 3.XX and Version 4 will 4 .XX.
  • On version 1 panels, add 0021 to the point # to determine the 4 digit address of the point = point 1 is address 0022.
    • For example, remove point 1 from the program at address 0022 by entering: 00 #.
  • On version 2 panels, add 0017 to the point # and you will have the 4 digit address of the point = point 1 is address 0018.
    • For example, remove point 1 from the program at address 0018 enter a 00 #.
  • On version 3 panels, add 0017 to the point # and you will have the 4 digit address of the point = point 1 is address 0018.
    • For example, remove point 1 from the program at address 0018 enter a 00 #.
  • On version 4 panels, add 0030 to the point # and you will have the 4 digit address of the point = point 1 is address 0018.
    • For example, remove point 1 from the program at address 0031 enter a 00 #.
  • Exit Programming by pressing and holding the (*) key for 3 seconds (all versions).