 Perform the following procedure to set up open/close with the D5200 programmer:

NOTE: Receive a copy of panel programming before changing program.

1. Scroll to 8112 and press enter group .

2. Scroll to 8112G2 and press enter group .

3. Scroll to line 48 and enter an opening report code.

4. Scroll to line 49 and enter a closing report code.

5. Line 50 is restricted open/close and should be left at no for  normal open/close reporting.

6. Scroll to line 54 and set it to yes if using combination IDs.

7. Exit out of MAIN and go to AUX and entrer group.

8. Scroll to logger and enter group.

9. Scroll to line 6.5, send O/C, and set to yes .

10. Send to panel.