How to interpret the D8125Mux LED status and how to return the card to default.

Operation LED Descriptions
 
LED StatusFunction
Flashing: 1/2 second on, 1/2 second off        The D8125MUX scans its programmed multiplex points and operates normally.
OFFA module fault is indicated.
ONThe Multiplex Point Programmer is connected to the D8125MUX.
Flash 2x-1x-2x-1x..., etc.D8125MUX EEPROM has been rest to factory default

To reset the D8125MUX EEPROM:
  1. Connect the D5060 Programmer to the 4-pin Program Port on the D8125Mux. 
  2. The LED changes from 1/2 second flash to steady on.
  3. Place a shoring bar over the reset pins.
  4. The LED flash pattern changes from steady on to flash to 2x-1x-2x-1x indicating the default is complete.