How to interpret the heart- beat LED status of the B208 zone expander.
Flash Pattern:
Flash at 1x/sec rate:
Normal operation.
Flash at 3x/sec rate:
An SDI2 communication error or the device has nothing programmed to it.
Steady ON:
A trouble condition exists.
Steady OFF:
Module is not powered or some other trouble condition prohibits the module from controlling the heartbeat LED.
OFF for 3 sec, then flashes:
Firmware version.
Example; if the Firmware version is 3.2.1, the LED pulses 3 times and pauses for 1 sec, pulses 2 times and pauses for 1 sec, then pulses 1 time. After flashing the Firmware version, the heartbeat LED stays OFF for 3 sec before indicating the module state.