How to interpret the heart- beat LED status of the B208 zone expander.

Flash Pattern:
  • Flash at 1x/sec rate:
    • Normal operation.
  • Flash at 3x/sec rate:
    • An SDI2 communication error or the device has nothing programmed to it.
  • Steady ON:
    • A trouble condition exists.
  • Steady OFF:
    • Module is not powered or some other trouble condition prohibits the module from controlling the heartbeat LED.
  • OFF for 3 sec, then flashes:
    • Firmware version. 

      Example; if the Firmware version is 3.2.1, the LED pulses 3 times and pauses for 1 sec, pulses 2 times and pauses for 1 sec, then pulses 1 time.  After flashing the Firmware version, the heartbeat LED stays OFF for 3 sec before indicating the module state.