How to interpret the message at the wireless interface: 'Range Limited', and correct the issue.

Connecting the wireless interface (ISW-D8125CW-V2, ISW-D8125CW or D8125INV) to Zonex 1 of a compatible D9412 (G, GV2 or GV3) panel automatically configures it for points 9 - 127. Connecting to Zonex 2 configures for points 129 - 247. To release the wireless interface from the incorrect point range, you must default the EEPROM.


To default the EEPROM:

  1. Access the menus by entering the correct passcode and pressing [Enter]. Note: The default passcode is 123456.
  2. Select 3 to clear EEPROM from a ISW-D8125CW-V2 and ISW-D8125CW, or select 4 to clear EEPROM from a D8125INV.