How to interpret the panel executing Skeds 18-49 when only skeds 1-17are available.

  • The D7212B and D9112B has programming available for up to 16 Opening and Closing windows.  
  • An opening in Window 1 displays as Sked 18 and a close in Window 1 displays as Sked 19. The panel would indicate Opens and Closes in windows 1-16 as follows:

 

  • Window     Open          Close          Window     Open        Close
  •       1               Sked 18          Sked 19                9             Sked 34        Sked 35
  •       2               Sked 20          Sked 21              10            Sked 36        Sked 37
  •       3               Sked 22          Sked 23              11            Sked 38        Sked 39
  •       4               Sked 24          Sked 25              12            Sked 40        Sked 41
  •       5               Sked 26          Sked 27              13            Sked 42        Sked 43
  •       6               Sked 28          Sked 29               14           Sked 44        Sked 45
  •       7               Sked 30          Sked 31               15           Sked 46        Sked 47
  •       8               Sked 32          Sked 33               16           Sked 48        Sked 49