How to program opening and closing reports on the 7000/9000 series panels

 1) Under phone routing in panel wide parameters, set area O/C report to yes for the route group being used to send reports to CS.

2) Set area only under area wide parameters to yes.

3) Under user authority, set area O/C to a value of E (Enable) for all authority levels that the Opening and Closing reports are required.