Follow these steps:

  1. On the control panel board, remove the wires from Terminals 30 and 31.
  2. Plug the D5200 programmer into the control panel's program port.
  3. Enter group into D8112 , and select the appropriate D8112 control panel type.
  4. Momentarily short Terminal 29 to Terminal 32.
  5. Press [Receive Copy] on the D5200.

The control panel's programming is now copied to the D5200.