How to set the test report time on the 190 Test Report Timer module for the 4012/8012 panel.

The 190 comes preset to trip once every 24 hours. To adjust this time you have a series of jumpers that must be cut.

REPORT INTERVAL        CUT JUMPERS

  • 1hour ...................ABCE
  • 2...........................BCE
  • 3...........................ACE
  • 4...........................CE
  • 6...........................BE
  • 8...........................E
  • 12.........................CDE
  • 1 DAYS..................NONE
  • 2...........................DEF
  • 3...........................EG
  • 4...........................DG
  • 5.......................... FG
  • 6..........................DEH
  • 7..........................EFH
  • 8..........................DFH
  • 9..........................GH
  • 10........................DEFGH

The test interval time will then need to be set. There is a black button which is used to zero the clock to the present time, and a red button which is used to advance the timer clock up in hour intervals. Each flash of the LED indicates a one hour increase.

 