Skip to main content

How to Use Master Arm No Exit Feature

Select whether or not the arming state for an area changes from Master Armed to Perimeter Armed if no perimeter points with delay response are faulted during Exit Delay.

Only the final armed state is reported and displayed at the keypads.

*Note - When upgrading a non-GV2/GV3 control panel account to a GV2/GV3 control panel account, RPS forces the default to No.

Parameter Options

  • Yes: Switch the arming state to Perimeter if no Perimeter Delay point faults occurred.
  • No: Keep the area in Master Arm if no Perimeter Delay point faults occurred.

Part numbers D7212GV2, D7412GV2, D9412GV2, D7412GV3, D9412GV3, D7412GV4, D9412GV4, B3512, B4512, B5512, B8512G, B9512G