Skip to main content

How to use the B Series panel Battery supervision and Discharge - Recharge Schedule.

 B-Series Battery discharge and recharge schedule

Discharge Cycle

AC Off

AC Fail Report when programmed.

13.65 VDC

Charging float level.

12.1 VDC

Low Battery Report sent if programmed.

10.2 VDC

Minimum operational voltage. Keypads display low battery

Messages.

Recharge Cycle

AC On

Load shed relay reset; battery charging begins; Battery Trouble and AC Restoral Reports sent.

13.4 V

Battery Restoral Report sent. Battery float charged.