Skip to main content

How to use the Sensor Trouble Monitor in the D4412 or D6412.

Sensor Trouble Monitor:

  • Enables/disables reporting the sensor trouble monitor fault condition.
  • This feature does not apply to fire point types or non-fire 24-hour point types.
  • If a point is set up with sensor trouble monitor set to yes, and the point is not tripped with in the time frame allowed the panel generates a trouble.
  • Sensor Trouble Monitor time is located in the Global point configuration:

    This parameter determines the number of days (0 to 99) that the panel can function without sensor (point) activity (time accumulates only when the area is off/disarmed). This feature is assigned by Point Index in Point Options 1. This feature does not apply to fire point types or non-fire 24-hour point types, only controlled points. If there is no sensor activity after the entered time period, a trouble report is sent

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.