Skip to main content

FAQ: Power consumption of the heater & blower: UHO-HBGS-61 including temperature to turn ON & OFF

Question

  1. At what temperatures does the factory installed heater turn on and off? 
  2. Does the blower turn on and off with the heater or does it run continuously? 
  3. What is the power consumption of the heater?
  4. What is the power consumption of the blower?

Answer

UHO Housings – Blower, Fan, Defroster, Heater Control & Power

UHO-POE-10: 

DeviceTemperature ON/OFF
Hysteresis
Power
(Watts)
Blower 1For cooling:
On @ > 35 °C +/- 2 °C
Off @ < 30 °C +/- 2 °C
For Heating:
It is On/Off at the same temperature as the heater.
On @ < 5 °C +/- 5 °C
Off @ 15 °C +/- 5 °
1.5
FanAlways On2.0
HeaterOn @ < 5 °C +/- 5 °C
Off @ 15 °C +/- 5 °C
5.0

UHO-XXXX-11/51/61:

DeviceTemperature ON/OFF
Hysteresis
Power
(Watts)
BlowerAlways On2.5
HeaterOn @ < 5 °C +/- 5 °C
Off @ > 15 °C +/- 5 °C
30.0
DefrosterAlways On8.0