FAQ: Power consumption of the heater & blower: UHO-HBGS-61 including temperature to turn ON & OFF
Question
- At what temperatures does the factory installed heater turn on and off?
- Does the blower turn on and off with the heater or does it run continuously?
- What is the power consumption of the heater?
- What is the power consumption of the blower?
Answer
UHO Housings – Blower, Fan, Defroster, Heater Control & Power
UHO-POE-10:
Device | Temperature ON/OFF Hysteresis | Power (Watts) |
---|---|---|
Blower 1 | For cooling: On @ > 35 °C +/- 2 °C Off @ < 30 °C +/- 2 °C For Heating: It is On/Off at the same temperature as the heater. On @ < 5 °C +/- 5 °C Off @ 15 °C +/- 5 ° | 1.5 |
Fan | Always On | 2.0 |
Heater | On @ < 5 °C +/- 5 °C Off @ 15 °C +/- 5 °C | 5.0 |
UHO-XXXX-11/51/61:
Device | Temperature ON/OFF Hysteresis | Power (Watts) |
---|---|---|
Blower | Always On | 2.5 |
Heater | On @ < 5 °C +/- 5 °C Off @ > 15 °C +/- 5 °C | 30.0 |
Defroster | Always On | 8.0 |