Skip to main content

How are the recordings displayed in Op Client when using ANR with 'alarm only' recording set?

Question

How are the recordings displayed in Op Client when using ANR with 'alarm only' recording set?


Project set-up:

  • Bosch Camera
  • ANR feature enabled on DIP 5000 AIO running BVMS 11.0
  • camera records motion on the iSCSI
  • SD card is configured to alarm recording


Answer

When using ANR function in combination with 'alarm only' recording , recording 1 is with only the motion recorded.

When going to the ANR recordings these are continuous and does not have recorded only the motion.

This is normal and as designed, because when using ANR mode, the settings for the Secondary Recorder are ignored, ANR SD Card recording will always be continuous.

  • The primary recorder will record as programmed Alarm Only, Continuous, Alarm+Continuous etc.
  • In the event that there was a network outage, only the alarm snippets are transferred to iSCSI.


Recording 1 with alarm recording:



ANR recording:


Note:

The pre-alarm time is not going to be set inside the camera as the post-alarm time is as programmed in BVMS

If you use VRM standalone, and configure ANR, the Recorder 2 section is blank - you are not permitted to make any config to Rec2 in ANR mode.


Other useful Knowledge Base articles related to ANR: