How to set MIC Inteox to deliver IVA events to Genetec?

The article describes how to ensure the delivery of the IVA events to Genetec Security Center via Hybrid Driver ( Other ( CPP13 or newer) driver )

Symptom:

Motion detection for a PTZ Preset does not alert for VCA rule created on Camera (Mic Inteox) itself, instead only alert for VCA rule created via ONVIF interface via Genetec.

Step-by-step guide

To correct the behavior, Genetec Security Center should be configured to let the unit manage its own VCA rules.