Is Scenario selection (IVA Calibration) not visible in Bosch Configuration Manager v7.70.0090?

Question

Is Scenario selection (IVA Calibration) not visible in Bosch Configuration Manager v7.70.0090?

When using Bosch cameras for IVA Calibration performed with Bosch Configuration Manager 7.70.0090, the Scenario selection is not there anymore, and by default it selects bird's eye view.

In Perspective vertical elements will give errors “vertical line does not fit to bird eye view”.

  • Affected camera platforms are CPP 13, CPP 14 and CPP 7.3 (with IVA chipset).
  • CPP 4 and CPP 7.3 (EVA models) are not affected.

Answer

The solution is: Download and use Bosch Configuration Manager 7.62 until this will be fixed in the next release.