How to Configure Duress Code on the DS7400Xi 3+ Panel


Issue

Setting up the duress code on the DS7400XI 3+.

Solution

1. Enter the program mode

A. At the master keypad, enter the programmers code + #0. Ie...9876#0

Keypad should display:

Prog.mode, the version and adr =

2. Enter a (2) digit report code in address 0322. Ie...032210#; this would be an example of a valid entry for the contact id mode.

3. Exit program mode

A. At the keypad press and hold the star(*) key for 3 seconds and release it. You now should be out of the program mode, keypad should not display prog. mode anymore.

4. Assign the duress code to an available user #.

A. At the keypad enter a master code followed by #0. Keypad now should scroll through an options menu.

B. Press 0 then follow the instructions on the keypad. A duress code is authority level 5.

Test the duress.

The system should be armed and the exit delay time expired when disarming with the duress.