How to prevent wireless points from going into swinger bypass


Digit two of the point code will determine whether swinger shunt is active for a point.

  • A value of 3,4,8, or 9 will provide swinger shunt.

  • A value of 0,1,2,5,6, or 7 will disable swinger shunt.

Refer to the 2000 series program entry guide for specific functions of these digits