How to Troubleshoot False Alarms on the DS453Q & DS455Q


Issue

What would cause a constant alarm violation?

Solution

  1. Something is blocking the beams.

  2. Optical modules or covers need cleaning.

  3. Optical modules misaligned.

  4. Wiring fault.

Solution:

  1. Remove the object.

  2. Clean the optical modules and the covers.

  3. Realign.

  4. Check wiring.