How to Set the DS7090 or DS7090i to Factory Default


Issue

What are the steps to default a DS7090 or DS7090i?

Solution

To set panel back to factory default perform the following:

Caution - This will erase all programming except for the phone numbers. What may prevent the panel from being set to factory default is a security feature called anti-takeover. If this is enabled the panel will not be able to be set back to factory default

Enter into program mode by the installer code # 0 ( 98765 # 0 ) is the default code, or short the little silver dots next to the last zone on the panel for 4 seconds with a jumper wire.

** Enter 839#, the beeper should sound for steady.

Short the same 2 pins, and the panel should be back to factory default.

** When the step is followed and a 3-beep error tone is generated while after 839# is entered. This panel is lock and will need to be reset at Bosch Security System for a fee. Contact our repair department a 800-289-0096 https://community.boschsecurity.com/data:image/png;base64,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 Ex 4220 M - F 8 a.m. - 5 p.m. EST