How to configure the B-Series Panel onboard relays.


 The B-Series panel onboard relay can be configured for either:
  • Aux Power

  • Common output

  • Standard Form-C relay

Aux Power configuration,
Right two pins covered, the C terminal has 12Vdc available and upon activation will switch to the NO terminal. 

https://community.boschsecurity.com/t5/image/serverpage/image-id/916iF526354C7BF30563/image-dimensions/156x282?v=v2

Relay A turned off, NO to Common reads 0Vdc.
Relay A turned on, NO to Common reads +12Vdc.

Aux Common configuration
Left two pins covered, the C terminal is Common.  Upon activation Common is switched to the NO terminal.

https://community.boschsecurity.com/t5/image/serverpage/image-id/917iDDC1AAF41FBF3739/image-dimensions/141x263?v=v2

Relay A turned off, NO to Aux= 0Vdc
Relay A turned on, NO to Aux= 12Vdc

Dry Contact Configuration
No jumper used, NO and C and NC works as a standard dry contact.  

https://community.boschsecurity.com/t5/image/serverpage/image-id/918i743075F964CCC1F3/image-dimensions/151x275?v=v2

Relay A turned off, NO to C= Open, NC to C= Short
Relay A turned on, NO to C= Short, NC to C= Open