The 190 comes preset to trip once every 24 hours. To adjust this time you have a series of jumpers that must be cut.
REPORT INTERVAL CUT JUMPERS
-
1hour ...................ABCE
-
2...........................BCE
-
3...........................ACE
-
4...........................CE
-
6...........................BE
-
8...........................E
-
12.........................CDE
-
1 DAYS..................NONE
-
2...........................DEF
-
3...........................EG
-
4...........................DG
-
5.......................... FG
-
6..........................DEH
-
7..........................EFH
-
8..........................DFH
-
9..........................GH
-
10........................DEFGH