How to set the test report time on the 190 Test Report Timer module for the 4012/8012 panel.


The 190 comes preset to trip once every 24 hours. To adjust this time you have a series of jumpers that must be cut.

REPORT INTERVAL        CUT JUMPERS

  • 1hour ...................ABCE

  • 2...........................BCE

  • 3...........................ACE

  • 4...........................CE

  • 6...........................BE

  • 8...........................E

  • 12.........................CDE

  • 1 DAYS..................NONE

  • 2...........................DEF

  • 3...........................EG

  • 4...........................DG

  • 5.......................... FG

  • 6..........................DEH

  • 7..........................EFH

  • 8..........................DFH

  • 9..........................GH

  • 10........................DEFGH

The test interval time will then need to be set. There is a black button which is used to zero the clock to the present time, and a red button which is used to advance the timer clock up in hour intervals. Each flash of the LED indicates a one hour increase.