Issue
Will an Answering Machine cause the D168A not to answer when accessed locally?
Solution
Some answering machines load down the phone line and cause it to go below 7 VDC. The D168A needs at least 7 VDC to properly process the DTMF tones.
Issue
Will an Answering Machine cause the D168A not to answer when accessed locally?
Solution
Some answering machines load down the phone line and cause it to go below 7 VDC. The D168A needs at least 7 VDC to properly process the DTMF tones.