How to Troubleshoot D4112 Unable to Arm


Overview: D4112 doesn’t arm or anything when code is entered at the keypad.

Issue

Nothing happens. Doesn’t arm or anything when code is entered at the keypad.

Solution

  • Connect programmer using coiled cord.

  • Plug in plastic RJ phone type plug into COMMUNICATOR female connector on 5200

  • Plug brown connector on other end of coiled cord to programmer connection on 4112

  • Press ON button on 5200

  • Type in password at PASSWORD prompt, press enter.

  • Top Line of 5200 shows PRODUCT HANDLERS

  • Using the up/down arrows scroll down until 4112. Please blinking cursor on 4112

  • Press RED Enter Group button

  • Place cursor on NEWRECORD

  • Short the Standby pin on 4112 to ground momentarily

  • Press RECV(COPY) button on programmer

  • Receiving will be displayed at the top line of the 5200 Display

  • Scroll down using arrow down key until cursor is on 2 PASSCODES

  • Press ENTER GROUP button

  • Passcode1 should have 234 in the field.

  • To change field, press CLEAR key and type in the code to be used.

  • Press enter

  • The code is restricted to 4 characters but the user enters a prefix of 1, 2, 3, 4, 5…depending upon the slot. Example: PASSODE1 shows 234. The user code will be 1234

 

*** NOTE: Also make sure that the panel has a valid and functioning analog line.  The functionality of the system is dependent upond successful communications.