The Standby (Reset) pin is not locked down.
-
The panel 12V backup battery is low or missing.
-
Using the wrong product handler, for example, using 2112 instead of 2212.
-
Too much Current Draw on panel. Disconnect devices from Aux Power and try again.
-
Noise or interference on the keypad Data Bus. Disconnect all wires on the panel data terminals.
-
Not enough free memory in the D5200 Programmer. There should be 60K free memory. Refer to KB article: How to Operate the D5200 Hand Held Programmer.
-
The 2212 handler may be corrupted in the D5200. Delete the 2212 handler and re-download it. Refer to KB article: How to Operate the D5200 Hand Held Programmer.
-
Low batteries in the D5200. Replace batteries using 4 C cells.
-
Trying to program a panel that is not powered up
-
The programming cord is not securely connected to the panel programming port or may be damaged. The DX4010V2 comes with a cord with a 4-pin Molex connector on one end and phone connector on other end. This cable may work as a substitute.