How to Troubleshoot Buzz On Fault Zone


Issue

The Command Center is sounding the trouble tone and the point is normal.

 Solution

Buzz on fault is set to 1 (default setting for Point Index 6 & 9). When buzz on fault is set to 1 the keypad will begin to buzz when the point is faulted and continue even after it is normalized until the user acknowledges it with a passcode or command 4.

https://community.boschsecurity.com/t5/image/serverpage/image-id/817iF04B1547D7C159D0/image-size/large?v=v2&px=999

 Part numbers D7212B, D9112B, D7212B1, D9112B1, D7212, D7412, D9112, D9124, D9412, D7412G, D7412G, D9124G, D9412G, D7412GV2, D7412GV2, D9124GV2, D9412GV2, D7412GV3,D7412GV3, D9412GV3, D7412GV4, D7412GV4, D9412GV4, B8512G, B9512G,