How to program a rex motion to shunt only


 This procedure allows the Request-to- Exit (REX) motion detector to shunt the door contact without tripping the strike/magnetic lock.

NOTE: The controller firmware version must be 3.34 or higher.

Disconnect the line driver from the master controller if it is administered by an administration kit.

  1. Ensure that a faceplate is connected to the controller.

  2. To enter faceplate programming:Press and hold [RESET] for two seconds and then release.Press it again for one second when the control panel starts to beep. " PASSWRD" appears on the display.

  3.  Type PAC1990 at the PASSWRD prompt.

  4. At the CMD prompt, type INST, and then press [ENT].

  5. Press [NXT] five times.The "ENTER SYS TYPE" prompt appears.

  6. Press [0][ENT][ESC].

  7. At the CMD prompt, type "D" , and then then press [ENT].

  8. Press [NXT] four times.

  9. At the "DR1 M2" prompt, type the channel number that you want to shunt.

  10. Press [ENT], and then press [ESC] twice. The door now shunts, but the lock does not release.