This procedure allows the Request-to- Exit (REX) motion detector to shunt the door contact without tripping the strike/magnetic lock.
NOTE: The controller firmware version must be 3.34 or higher.
Disconnect the line driver from the master controller if it is administered by an administration kit.
-
Ensure that a faceplate is connected to the controller.
-
To enter faceplate programming:Press and hold [RESET] for two seconds and then release.Press it again for one second when the control panel starts to beep. " PASSWRD" appears on the display.
-
Type PAC1990 at the PASSWRD prompt.
-
At the CMD prompt, type INST, and then press [ENT].
-
Press [NXT] five times.The "ENTER SYS TYPE" prompt appears.
-
Press [0][ENT][ESC].
-
At the CMD prompt, type "D" , and then then press [ENT].
-
Press [NXT] four times.
-
At the "DR1 M2" prompt, type the channel number that you want to shunt.
-
Press [ENT], and then press [ESC] twice. The door now shunts, but the lock does not release.