The Heartbeat, battery and AC LED's are used to indicate the operational status of the B520 Auxiliary Power Supply.
Heartbeat LED:
-
Flash 1x/ sec:
-
Normal State: Indicates normal operation state.
-
-
Flash 3x/sec:
-
Trouble State: Power exists, but no communication.
-
-
ON Steady:
-
Trouble State: Indicates a trouble condition exists.
-
-
OFF Steady:
-
LED Trouble State: Module is not powered, or some other trouble condition prohibits the module from controlling the heartbeat LED.
-
-
OFF for 3 sec, then flash pattern:
-
Firmware version* Firmware Version: For example, if the version is 3.2.1, the LED pulses 3 times and pauses for 1 sec, pulses 2 times and pauses for 1 sec, and then pulses 1 time. After flashing the Firmware version, the heartbeat LED stays OFF for 3 sec before indicating the module state.
-
Batt 1and Batt 2 LED:
-
Green, steady On LED:
-
Status of the battery is operational.
-
-
LED steady Off:
-
Missing battery.
-
-
Flashing:
-
Low battery.
-
-
Triple flash:
-
Battery charger failure.
-
AC LED:
-
Green, steady On LED:
-
The AC power is operational.
-
-
Pulsating LED (3 pulses per sec).
-
Battery test is being performed.
-
-
Flashing:
-
Low or failed AC.
-