How to change the sensitivity on the DS935Z motion detector


Configuring Detector

1 ON = LED ON

1 OFF = LED OFF

2 ON = Standard

2 OFF = Intermediate

3 ON and 4 OFF = 4 Day Motion Monitor

3 OFF and 4 ON = 30 Day Motion Monitor

3 OFF and 4 OFF = Motion Monitor Disabled

 

S2 - Sensitivity Mode

  • Standard Sensitivity: Recommended setting for maximum

false alarm immunity. Tolerates environment extremes on this

setting. Not recommended for Long Range or Barrier type

patterns. The detector is shipped in Standard Sensitivity

mode.

  • Intermediate Sensitivity: Recommended setting for any location

where an intruder is expected to cover only a small portion of the

protected area. Tolerates normal environments on this setting.

This setting will improve your intruder catch performance.