Issue
How can I setup Open/Close on a 2112 panel?
Solution
Using RPS/RAMIV
-
Connect to the control via modem/RPS and receive all panel data and save to your RPS database.
-
Go to the Open/Close section of the program.
-
Turn on All-On reports by selecting Yes.
-
Turn on Part-On reports by selecting Yes.
-
Save your changes and send the changed data back to the control. Test it out.
Using 5200
-
Latch the installer clip on the control panel and receive a fresh copy of the panel data.
-
After you see Receive Successful on your 5200, go to the Open/Close section of the program.
-
Using the white SPACE bar on the 5200 press it to toggle NO to YES to turn on O/C for both ALL ON and PART ON.
-
4. Press the red SEND LOAD key, disconnect the programmer and unclip the installer switch. Test.
Part numbers D2112, D5200 RPS, RAMIV