Skip to main content

BRS NetLimiter may become not registered

Possible causes and solution(s)

  • Causes

Related Products
 

Bosch Recording Station (BRS) version 8.9 and later


The UDP tunneling cannot be configured on BRS.

Network cards are grayed out.


  • Solution

Under certain circumstances BRS NetLimiter may become not registered.
The network cards are not shown in Configuration > Security and Network > Network settings.

In that case, register BRS NetLimiter manually:
1. Close BRS application
2. Control Panel > System and Security > Administrative Tools > Services > Bosch Networking Service
   a) Set "Startup Type" to "disabled"
   b) Stop service
   c) In a console window with administrative rights, enter "C:\Program Files\Bosch\Recording Station\NetLimiterServer" /service
   d) Set "Startup Type" to "Automatic"
   e) Start service
3. Start BRS application





JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.