BRS NetLimiter may become not registered




Possible causes and solution(s)

  • Causes

Related Products
 

Bosch Recording Station (BRS) version 8.9 and later


The UDP tunneling cannot be configured on BRS.

Network cards are grayed out.


  • Solution

Under certain circumstances BRS NetLimiter may become not registered.
The network cards are not shown in Configuration > Security and Network > Network settings.

In that case, register BRS NetLimiter manually:
1. Close BRS application
2. Control Panel > System and Security > Administrative Tools > Services > Bosch Networking Service
   a) Set "Startup Type" to "disabled"
   b) Stop service
   c) In a console window with administrative rights, enter "C:\Program Files\Bosch\Recording Station\NetLimiterServer" /service
   d) Set "Startup Type" to "Automatic"
   e) Start service
3. Start BRS application