General information:
-
Since FW 10.40.0055, SNMPv3 traps have been included for the Videojet Decoder 75xx
-
SNMPv1 is not supported by the decoders
-
3 traps are supported:
-
Processor overload - 1.3.6.1.4.1.3967.7.3.1.1
-
Memory overload - 1.3.6.1.4.1.3967.7.3.1.2
-
Thermal overload - 1.3.6.1.4.1.3967.7.3.1.3
-
-
MIB file: BOSCH-VJD_SNMPv3.mib
-
What is the VideoJet VJD-75xx SNMP get/set port:
-
VJD-75xx don't offer a SNMP server which answers to incoming SNMP get or set requests, they only send traps when an overload situation starts and ends.
-
Step-by-step guide
Configuring SMNPv3:
-
Open CM or BVMS CC and select the VJD's
-
Navigate to Network- Network Management.
-
Select SNMPv3
-
Enter SNMP Host address - up to 2 supported host addresses
-
Enter Trap User username
-
Set Authentication protocol to SHA1, MD5 or None
-
Note: ensure the trap receiver accepts encrypted traps and other auth modes than SHA1.
-
-
Enter Authentication password
-
Set Privacy protocol to AES, DES or None.
-
-
Save
Known restriction:
-
Overload messages and traps may appear too sensitive in cases where display refresh rates are lower than video stream frame rates.