FAQ: Power consumption of the heater & blower: UHO-HBGS-61 including temperature to turn ON & OFF




Question

  1. At what temperatures does the factory installed heater turn on and off? 

  2. Does the blower turn on and off with the heater or does it run continuously? 

  3. What is the power consumption of the heater?

  4. What is the power consumption of the blower?

Answer

UHO Housings – Blower, Fan, Defroster, Heater Control & Power

UHO-POE-10: 

image-2023-5-9_14-43-21.png

Device

Temperature ON/OFF
Hysteresis

Power
(Watts)

Blower 1

For cooling:
On @ > 35 °C +/- 2 °C
Off @ < 30 °C +/- 2 °C
For Heating:
It is On/Off at the same temperature as the heater.
On @ < 5 °C +/- 5 °C
Off @ 15 °C +/- 5 °

1.5

Fan

Always On

2.0

Heater

On @ < 5 °C +/- 5 °C
Off @ 15 °C +/- 5 °C

5.0


UHO-XXXX-11/51/61:

image-2023-5-9_14-47-11.png

Device

Temperature ON/OFF
Hysteresis

Power
(Watts)

Blower

Always On

2.5

Heater

On @ < 5 °C +/- 5 °C
Off @ > 15 °C +/- 5 °C

30.0

Defroster

Always On

8.0